The basic rule
A locker is occupied for the whole visit. So what counts is not how many members you have, but how many people are in the building at the same time in your busiest hour. Add a margin of 15 to 25% to that number.
Number of lockers = peak simultaneous visitors × 1.15 to 1.25.
An example: 60 people at once means 70 to 75 lockers. The margin covers the time when one group is still getting dressed and the next is already arriving.
Where to get the figure
- Existing site: from your access system. Look for the highest number of people present at once in recent months, not the average.
- New site: from your business plan. How many people do you expect at once in the busiest hour when the site is full?
- Separate changing rooms: calculate men's and women's separately, from the actual split of visitors.
Group classes
When classes run back to back, two groups are in the changing room at the changeover. A studio for 20 people therefore occupies up to 40 lockers, although only 20 are training. If you have several studios on the same timetable, the effect adds up. Staggering start times between studios by 15 minutes lowers the peak in the changing room without a single extra locker.
Pools and wellness
A visit to a pool or wellness centre lasts longer than a workout, so more guests are present at once relative to daily visits. Start from the maximum permitted occupancy of the site. Families often use one larger locker instead of several small ones, so plan some lockers at 400 mm width.
Hotel spas
Start from the capacity of the spa, not the number of rooms. Some hotel guests change in their room and arrive in a bathrobe, while outside guests always need a locker.
Staff
Count staff lockers separately. They are assigned permanently, so guests cannot use them even when the employee is not at work.
How much wall that means
Convert the number of lockers into wall length by dividing it by the number of doors per column and multiplying by the column width.
- 75 lockers, 350 mm wide, two doors: 38 columns, about 13.3 m of wall.
- 75 lockers, 300 mm wide, three doors: 25 columns, 7.5 m of wall.
- 75 lockers, 400 mm wide, one door: 75 columns, 30 m of wall.
For a sense of room size: a changing room of 6 × 4.5 m takes about 30 lockers, 7.2 × 6.5 m about 85 and 9 × 7 m about 120, including aisles and benches.
When you run out of lockers
If the changing room is full at peak time, check three things before expanding: whether class times overlap, whether guests keep lockers longer than their visit, and whether the run has single-door columns that could be replaced with two-door ones. Only then plan an extra run.
Leave room to grow
In the very first layout, decide where an extra run or island would go later, and do not put benches or mirrors there that are hard to move.
Once you know the number, read how to lay the lockers out in the room.
In the configurator you enter your room and see how many lockers fit.
Open the configurator